Holy Instrument · Suzhou Holy Instrument · Holy InstrumentOptical Inspection Instruments · QA Inspection Instruments · Metallographic Equipment
Hotline0512-65657743中文EnglishMobile13914063216Emailsuzhou@holyinst.com
Hotline0512-65657743
PRODUCT DETAIL

X-ray Fluorescence Thickness Gauge

X-ray Fluorescence Thickness Gauge
X-ray Fluorescence Thickness GaugeX-ray Fluorescence Thickness GaugeX-ray Fluorescence Thickness Gauge
Reliability Test › Coating & Film Thickness Measurement

X-ray Fluorescence Thickness Gauge

The X-ray Fluorescence Thickness Gauge provides non-destructive measurement of coating and film thickness and can analyze multilayer coatings and alloy composition.

Product DetailsDETAILS

Product Introduction

The X-ray fluorescence coating thickness gauge is an instrument that irradiates a sample with X-rays and measures the intensity of secondary fluorescent X-rays generated by the coating and substrate to non-destructively determine the thickness of a coating or film. This method is a non-contact, non-destructive measurement and is listed as a standard method for coating thickness measurement by standards such as ISO 3497 and JIS H8501; a single measurement yields the coating thickness, and complex coating structures can be handled through multi-layer and alloy coating analysis functions. It is widely used for coating thickness control in surface treatment industries such as electronic connectors, PCB, hardware electroplating, and jewelry.

Main Technical Parameters

  • Measurement method: X-ray fluorescence spectrometry (XRF), non-destructive, non-contact
  • Measurable element range: atomic number 22 (Ti) to 83 (Bi); elements with atomic number below 21 can be measured by the absorption method
  • Measurable coating thickness range: approximately 0.01 to 30 μm, depending on coating structure and elements
  • Number of coating layers: up to 5 coating layers can be measured simultaneously
  • Measurement spot: circular Φ0.05 to 0.2 mm, or square 0.025 × 0.2 mm
  • X-ray tube: micro-focus air-cooled high-power X-ray tube, tube voltage 50 kV
  • Detector: high-resolution proportional counter / semiconductor detector, depending on configuration
  • Focusing method: CCD camera observation and positioning, laser auto-focus
  • Measurement time: typically adjustable from 10 to 300 seconds
  • Software functions: thin-film FP standardless analysis, multi-layer and alloy coating analysis, report output
  • Power supply: AC 220 V, 50/60 Hz

Product Features

  • Non-contact, non-destructive measurement, causing no damage to the appearance or performance of finished products
  • Fast measurement speed, enabling single-point or batch measurement points to be completed in a short time
  • Supports measurement of multi-layer, alloy, and ultra-thin coatings
  • The sample stage can move automatically, supporting point measurement, area measurement, and multi-point programmed measurement
DocumentsDOWNLOADS